Code
C2212
Drum motor C startup error
Drum motor C is not stabilized within 5 s
since the motor is activated.
C2213
Drum motor M startup error
Drum motor M is not stabilized within 5 s
since the motor is activated.
C2214
Drum motor Y startup error
Drum motor Y is not stabilized within 5 s
since the motor is activated.
C2231
Drum motor K main sensor error
No signal is input to the sensor for 1.5 s
continuously.
C2232
Drum motor C main sensor error
No signal is input to the sensor for 1.5 s
continuously.
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Check the connection of connector YC6 on
connector termi-
the motor control PWB and the connector of
nals.
the drum motor C, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective drum
Replace the drum motor C.
motor C.
Defective PWB.
Replace the motor control PWB or engine
PWB and check for correct operation.
Poor contact in the
Check the connection of connector YC5 on
connector termi-
the motor control PWB and the connector of
nals.
the drum motor M, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective drum
Replace the drum motor M.
motor M.
Defective PWB.
Replace the motor control PWB or engine
PWB and check for correct operation.
Poor contact in the
Check the connection of connector YC7 on
connector termi-
the motor control PWB and the connector of
nals.
the drum motor Y, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective drum
Replace the drum motor Y.
motor Y.
Defective PWB.
Replace the motor control PWB or engine
PWB and check for correct operation.
Poor contact in the
Check the connection of connector YC8 on
connector termi-
the motor control PWB and the connector of
nals.
the drum motor K, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective drum
Replace the drum motor K.
motor K.
Defective PWB.
Replace the motor control PWB or engine
PWB and check for correct operation.
Poor contact in the
Check the connection of connector YC6 on
connector termi-
the motor control PWB and the connector of
nals.
the drum motor C, and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective drum
Replace the drum motor C.
motor C.
Defective PWB.
Replace the motor control PWB or engine
PWB and check for correct operation.