Kyocera FS-C8500DN Service Manual page 317

Colour printer for a3 formats
Hide thumbs Also See for FS-C8500DN:
Table of Contents

Advertisement

Connector
Pin No.
YC30
1
Connected to
2
the high volt-
3
age control
4
PWB
5
6
7
8
9
10
11
12
13
YC35
1
Connected to
2
the eject
3
PWB
4
5
6
7
8
9
10
11
12
YC38
1
Connected to
2
the LSU fan
3
motor and
4
inner temper-
ature sensor
1
YC39
1
Connected to
2
the develop-
ing fan motor
5
Signal
I/O
+5V1
O
+5V1
O
SGND
-
SGND
-
PWB SCLK BUF
O
PWB SDI BUF
I
PWB SDO BUF
O
HVU SEL BUF
O
PWB RDY BUF
I
DLP1 HV REM
O
DLP2 HV REM
O
DLP3 HV REM
O
DLP4 HV REM
O
+24V1
-
SGND
-
SGND
-
MCV_ENBL
-
FGND
-
MCV_FED_COUNT
O
MCV_EJ_COUNT
O
MCV_COPY_SIG
-
MCV_UART_TXD
-
SGND
-
MCV_UART_RXD
-
SGND
-
LSU FAN REM
O
+24V1
O
SGND
-
POLYGON TEMP
I
+24V1
O
SIDE_DLP_FAN
O
Voltage
5 V DC
5 V DC power to HVCPWB
5 V DC
5 V DC power to HVCPWB
-
Ground
-
Ground
0/3.3 V DC (pulse) HVCPWB clock signal
0/3.3 V DC (pulse) HVCPWB serial communication data signal
0/3.3 V DC (pulse) HVCPWB serial communication data signal
0/3.3 V DC
HVCPWB select signal
0/3.3 V DC
HVCPWB ready signal
0/3.3 V DC
Developing bias M: On/Off
0/3.3 V DC
Developing bias C: On/Off
0/3.3 V DC
Developing bias Y: On/Off
0/3.3 V DC
Developing bias K: On/Off
-
Not used
-
Not used
-
Not used
-
Not used
-
Not used
0/24 V DC
FSSOL2: On/Off (ACT)
0/24 V DC
FSSOL2: On/Off (REV)
-
Not used
-
Not used
-
Not used
-
Not used
-
Not used
0/24 V DC
LSUFM: On/Off
24 V DC
24 V DC power to LSUFM
-
Ground
Analog
INTEMS1 detection signal
24 V DC
24 V DC power to DEVFM5
0/24 V DC
DEVFM5: On/Off
Description
2-3-19
2KA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents