Programming Department Calling Group Overflow for a DIL to the Master
Number
1.
2.
3.
2 - 366
47-06-10 System Administrator (System Admin) on page
47-06-11 Dialing Option on page
47-06-12 Next Call Routing Mailbox (Next CR Mbox) on page
Set up the Department Group.
16-02-01
Department Group Assignment for Extensions
Assign telephone extensions to a Department Group.
Assign the InMail extensions to a unique Department Group (e.g., 2).
No other extensions should be in this group.
These extensions are the extensions the system assigns to the InMail.
Do not use Department Group 1.
Be sure to set up the Department Group in order. (For example, the first
extension should be order 1, the second order 2, etc.)
11-07-01
Department Group Pilot Numbers
Assign master (pilot) numbers to Department Groups.
Set up a DIL for the Department Group.
22-02-01
Incoming Call Trunk Setup
Assign Service Type 4 to each trunk you want to be a DIL. Make a separate
entry for each Night Service mode.
By default, trunks are Service Type 0 (Normal).
.
22-07-01
DIL Assignment
For each DIL you want to ring the Department Group directly, enter the
Department Group master number.
By default, there are no DIL destinations programmed.
.
22-08-01
DIL/IRG No Answer Destination
For each DIL to the Department Group master number, enter 102 to make
InMail the overflow (no answer) destination.
By default, the overflow (no answer) destination is Incoming Ring Group 1.
.
Set how long a DIL rings in the Department Group before overflow occurs.
22-01-04
DIL No Answer Recall Time
Set how long ( 0~64800 seconds) the DIL rings in the Department Group
before overflow occurs.
By default, this interval is 0 (no overflow).
.