NEC univerge sv8100 User Manual page 174

Hide thumbs Also See for univerge sv8100:
Table of Contents

Advertisement

Issue 7.00
4.
2-Digit Extension Numbering Example
When setting up 2-digit extension numbering in a SV8100 with InMail, do not use
extensions 10~32. Although you can set up this application in 11-01-01 System Numbering
and 11-02-01 Extension Numbering, Subscriber Mailboxes assigned in 47-02-02 Mailbox
Number do not function. This is because mailboxes 1~32 are reserved for Routing
Mailboxes and cannot be reassigned.
The following example assigns a 2-digit extension number (26) to station port 6 and
enables the Subscriber Mailbox for extension 26. It also changes the * and # digits in
the active Dial Action Table to allow Quick Message and Remote Logon to the new
2-digit extension.
1.
2.
3.
2 - 166
Modify the Dial Action Tables to accommodate the new numbering.
TRF Action - Screened Transfer (1) (TRF) on page
Refer to
.
Optionally modify the active Dial Action Table actions for the new extension
numbers.
For example, to allow Automated Attendant callers to dial extension 5000, for
digit 5:
Change the Action to UTRF (2) or TRF (1).
Change the Data to XXXX.
By default (in the above example), the digit 5 is undefined.
.
InMail Does Not Support 2-Digit Extension Numbers 10-16
Enable 2-digit extension numbers 20~29.
11-01-01
System Numbering
In 11-01-01 Digit for the digit 2x, enter 2.
In 11-01-01 Type for the digit 2x, enter 2.
By default, the digit 1 is set up as a 3-digit extension number (100~199).
.
Change the extension number for port 6 to 26.
11-02-01
Extension Numbering
For extension port 6, enter 26.
By default, extension port 6 is assigned to extension 106.
.
Change the mailbox number to match the new extension number.
47-02-02
Mailbox Number (Mailbox Number)
For mailbox 6, assign mailbox number 26.
By default, mailbox 6 is assigned to mailbox number 106.
.
3-449.