Service cases - hardware
4.1 PPU 24x.2/26x.2/28x.2
4.1.3

This is how you install the PPU

Installing
Procedure:
1. Now, install the system CompactFlash Card into the new PPU.
2. Installing a new PPU.
3. Attach and tighten the clips to fix the PPU.
4. Connect the ground connections and tighten.
5. Insert the PN1, PN2 interfaces that were withdrawn.
6. Insert the Ethernet cable that was withdrawn at X130.
7. Insert the DRIVE-CLiQ cable that was withdrawn at X100 – X102
8. Insert the handwheel terminal that was withdrawn at X142.
9. Insert the digital input/output terminals that were withdrawn at X122, X132, X142.
10. Reconnect power supply X1.
11. Retighten the strain relief assemblies.
12. Close the cabinet and switch-on the system again.
13. Read-in the available data backup.
Note
Changing the MAC address
When replacing the PPU, then the MAC address of Ethernet interface X130 changes:
Notify the customer or the system administrator of the new MAC address.
78
(refer to Chapter This is how you insert the system CompactFlash Card (Page 81))
CAUTION
Ensure that all of the connectors and screws are correctly tightened or latched and
inserted.