6. Fix the metal cover to the housing using the screw.
PPU as replacement part
Note
For a PPU as replacement part (spare part), a system CompactFlash Card is not supplied.
4.2.2
This is how you insert the system CompactFlash Card
Precondition
The control cabinet and the PPU are in a no-voltage condition or the PPU has already been
removed.
CAUTION
Electro-static discharge (ESD)
The system CompactFlash card must only be inserted or removed in a no-current
condition.
Before you touch the CompactFlash Card, discharge yourself at the cabinet or at the
ground terminal.
Hardware and Software
Service Manual, 03/2011, 6FC5397-5DP40-0BA0
Note
When removing the system CompactFlash Card, carefully ensure that neither the screw
nor the system CompactFlash Card falls into the PPU or the machine.
Service cases - hardware
4.2 Replacing the system CompactFlash Card
81