This is how you install a TM54F

Installing
Procedure:
1. Place the components on the mounting rail.
2. Then, swivel the components on the mounting rail so that the mounting catches click into
3. Slide the components along the mounting rail to either the left or right up to their final
4. Screw on the protective conductor connection.
5. If necessary, screw on the shield connection.
6. Insert the connectors for the digital inputs and outputs at X520 - X535.
7. Insert the DRIVE-CLiQ cables at X500 and X501.
8. Insert the connectors for the sensor and electronics power supply at X514 and X524.