Procedure:
1. Switch-off the control: Completely switch off the system. Check that the system is in a no-
2. Access the operator panel/control cabinet in which the machine control panel is located.
3. Using a multimeter, check the X10 power supply to ensure that the system really is in a
4. If it has not already been done, label all connectors that lead to the module now.
5. Withdraw the power supply X10 (
6. Release the strain relief of the Ethernet cable (
7. Remove the Ethernet cables from the X20 / X21 interface (port 1/port 2) (
8. Release other cables (e.g. the Emergency Stop cable or the button from the mini
9. Remove the ground connection by releasing the grounding screw (
10. Release the machine control panel from the control panel by releasing the clips.
11. Note down the set address S2 (
4.4.6
This is how you install the MCP 483C PN
Installing
Procedure:
1. Set DIL switch S2 (
2. Installing a new machine control panel.
3. Secure the clips to retain the machine control panel and tighten them.
4. Connect the ground connection (
5. Reconnect the other cables (e.g. the Emergency Stop cable or the button from the mini
6. Reinsert the Ethernet cables at the X20/X21 interface (port 1/port 2) (
7. Re-establish the Ethernet cable strain relief (
8. Reconnect the power supply X10 (
9. Close the cabinet and switch-on the system again.
Hardware and Software
Service Manual, 03/2011, 6FC5397-5DP40-0BA0
voltage condition and is locked-out so that it cannot be switched on again without the
appropriate authorization.
no-voltage condition.
Only then, can it be ensured that the cables are not interchanged.
handheld unit or from other command devices), if available.
⑪
) of the new module to what you previously noted down.
handheld unit or from other command devices), if available.
⑭
).
⑨
)
⑪
) at the DIL switch of the defective module.
①
).
⑨
).
⑭
).
Service cases - hardware
4.4 Machine control panels
④
)
①
).
④
).
99