Service cases - hardware

4.6 Expansion module NX10.3

4.6
Expansion module NX10.3
4.6.1

NX10.3 status displays

Status displays
The following status displays on the NX10.3 provide information about the module state:
LED
Color
RDY, H1
-
Green
Red
Yellow
DP1,
-
CU_LINK,
H2
Green
Red
110
State
Description
OFF
Electronics power supply outside the permissible tolerance range.
Continuous light
Component is ready.
Flashing light 2 Hz Writing to CompactFlash Card.
Continuous light
There is at least one fault (e.g., RESET, watchdog monitoring, basic system
fault).
NX10.3 is presently booting.
Flashing light
Error when booting: e.g. the firmware cannot be loaded into the RAM.
0.5 Hz
Continuous light
Firmware is being loaded into the RAM
Flashing light
Firmware cannot be loaded into the RAM.
0.5 Hz
Flashing light 2 Hz Firmware CRC error.
OFF
Electronics power supply outside the permissible tolerance range.
NX10.3 is not ready for operation.
Continuous light
CU_LINK is ready for communication and cyclic communication is running.
Flashing light
CU_LINK is ready for communication and no cyclic communication is
0.5 Hz
running.
Continuous light
At least one CU_LINK fault is present.
CU_LINK is not ready for operation (e.g., after switching on).