Chapter 5 Analog Modules
5.4.8.6 SMADC1ClrLed
Syntax
error_code SMADC1ClrLed(u_int8 PortNr, u_int8 LedNr);
Description
This function switches off one of the two LEDs fitted to the SM-ADC1.
Input
u_int8 PortNr
u_int8 LedNr
Output
error_code
Example
RetVal = SMADC1ClrLed(0, 2);
October 01, 1996
SM-Port number to be accessed
Number of the LED to switch off (1-2)
SUCCESS
E_SEEK
E-BMODE
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
©1996 PEP Modular Computers GmbH
SMART I/O User's Manual
if module was not initialised
if the module is unknown
5
Page 5 - 99