4.4.2 Specifications
Table 4-1: Specifications
Isolation
Input
Front panel
Options
Power con-
sumption
Temperature
range
Module weight
ID Byte
Page 4 - 54
Manual ID 09901, Rev. Index 0500
2.5 kV optoisolated towards the system
8 channels (80 V AC - 264 V AC)
Common neutral
< 0.5 mA input current
Input frequency range
Overvoltage protection (continu-
ous):
Switch-ON delay:
Switch-OFF delay:
High level:
Low level:
Green LEDs (switched on, when INPUT is active)
User-configurable RC filter on the last channel for INTx
generation
3 mW min., 70 mW max.
Standard:0° C to +70° C
Extended:-40° C to +85° C
38 g
$02, read by the SPI interface
Digital Modules
47-63 Hz
350 V AC
< 21 ms
< 16 ms
> 20 V
< 10 V
08 Jan. 98