5.2.8.5 SMADCSetSensorType

Syntax
error_code SMADCSetSensorType(u_int8 PortNr, u_int8
Description
This function checks if an SM-PT100 board is fitted on the specified port, if
the channel is valid, if the sensorCode is known and sets the gain, precision
and mode to their default values for the type of sensor connected.
Input
u_int8 PortNr
u_int8 channel
u_int16 sensorCode
Output
error_code
Example
RetVal = SMADCSetSensorType(0, 1, PT100);
Page 5 - 42
channel, u_int16 sensorCode);
Port number om module to set
(from 0 to 10)
Number of specified channel (0 to 3)
Code of the sensor (a list of PEP
defined sensor types can be found in the
file linear.h)
SUCCESS
If wrong type of module or no module
E_MNF
is fitted on the selected port
If wrong channel number is specified
E_PARAM
If sensor type is not known
E_BTYP
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).