GE T35 Instruction Manual page 281

Transformer management relay ur series
Hide thumbs Also See for T35:
Table of Contents

Advertisement

APPENDIX B
F222
ENUMERATION: TEST ENUMERATION
0 = Test Enumeration 0, 1 = Test Enumeration 1
F300
UR_UINT16: FLEXLOGIC™ BASE TYPE (6-bit type)
The FlexLogic™ BASE type is 6 bits and is combined with a 9 bit
descriptor and 1 bit for protection element to form a 16 bit value.
The combined bits are of the form: PTTTTTTDDDDDDDDD,
where P bit if set, indicates that the FlexLogic™ type is associated
with a protection element state and T represents bits for the BASE
type, and D represents bits for the descriptor.
The values in square brackets indicate the base type with P prefix
[PTTTTTT] and the values in round brackets indicate the descrip-
tor range.
[0] Off(0) this is boolean FALSE value
[0] On (1)This is boolean TRUE value
[2] CONTACT INPUTS (1 - 96)
[3] CONTACT INPUTS OFF (1-96)
[4] VIRTUAL INPUTS (1-64)
[6] VIRTUAL OUTPUTS (1-64)
[10] CONTACT OUTPUTS VOLTAGE DETECTED (1-64)
[11] CONTACT OUTPUTS VOLTAGE OFF DETECTED (1-64)
[12] CONTACT OUTPUTS CURRENT DETECTED (1-64)
[13] CONTACT OUTPUTS CURRENT OFF DETECTED (1-64)
[14] REMOTE INPUTS (1-32)
[28] INSERT (Via Keypad only)
[32] END
[34] NOT (1 INPUT)
[36] 2 INPUT XOR (0)
[38] LATCH SET/RESET (2 inputs)
[40] OR (2 to 16 inputs)
[42] AND (2 to 16 inputs)
[44] NOR (2 to 16 inputs)
[46] NAND (2 to 16 inputs)
[48] TIMER (1 to 32)
[50] ASSIGN VIRTUAL OUTPUT (1 to 64)
[52] SELF-TEST ERROR (see F141 for range)
[56] ACTIVE SETTING GROUP (1 to 6)
[62] MISCELLANEOUS EVENTS (see F146 for range)
[64 to 127] ELEMENT STATES
GE Multilin
F400
UR_UINT16: CT/VT BANK SELECTION
bitmask
0
1
2
3
4
5
F500
UR_UINT16: PACKED BITFIELD
First register indicates I/O state with bits 0(MSB)-15(LSB) corre-
sponding to I/0 state 1-16. The second register indicates I/O state
with bits 0-15 corresponding to I/0 state 17-32 (if required) The
third register indicates I/O state with bits 0-15 corresponding to I/0
state 33-48 (if required). The fourth register indicates I/O state with
bits 0-15 corresponding to I/0 state 49-64 (if required).
The number of registers required is determined by the specific
data item. A bit value of 0 = Off, 1 = On
F501
UR_UINT16: LED STATUS
Low byte of register indicates LED status with bit 0 representing
the top LED and bit 7 the bottom LED. A bit value of 1 indicates
the LED is on, 0 indicates the LED is off.
F502
BITFIELD: ELEMENT OPERATE STATES
Each bit contains the operate state for an element. See the F124
format code for a list of element IDs. The operate bit for element ID
X is bit [X mod 16] in register [X/16].
F504
BITFIELD: 3-PHASE ELEMENT STATE
bitmask
0
1
2
3
4
5
6
7
F505
BITFIELD: CONTACT OUTPUT STATE
0 = Contact State, 1 = Voltage Detected, 2 = Current Detected
T35 Transformer Management Relay
B.4 MEMORY MAPPING
bank selection
Card 1 Contact 1 to 4
Card 1 Contact 5 to 8
Card 2 Contact 1 to 4
Card 2 Contact 5 to 8
Card 3 Contact 1 to 4
Card 3 Contact 5 to 8
element state
Pickup
Operate
Pickup Phase A
Pickup Phase B
Pickup Phase C
Operate Phase A
Operate Phase B
Operate Phase C
B
B-45

Advertisement

Table of Contents
loading

Table of Contents