APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 29)
ADDR
REGISTER NAME
DD20
...Repeated for module number 17
DD22
...Repeated for module number 18
DD24
...Repeated for module number 19
DD26
...Repeated for module number 20
DD28
...Repeated for module number 21
DD2A
...Repeated for module number 22
DD2C
...Repeated for module number 23
DD2E
...Repeated for module number 24
DD30
...Repeated for module number 25
DD32
...Repeated for module number 26
DD34
...Repeated for module number 27
DD36
...Repeated for module number 28
DD38
...Repeated for module number 29
DD3A
...Repeated for module number 30
DD3C
...Repeated for module number 31
DD3E
...Repeated for module number 32
Direct I/O Alarms (Read/Write Setting)
DE00
Direct I/O Channel 1 CRC Alarm Function
DE01
Direct I/O Channel 1 CRC Alarm Message Count
DE02
Direct I/O Channel 1 CRC Alarm Threshold
DE03
Direct I/O Channel 1 CRC Alarm Events
DE04
Reserved (4 items)
DE08
Direct I/O Channel 2 CRC Alarm Function
DE09
Direct I/O Channel 2 CRC Alarm Message Count
DE0A
Direct I/O Channel 2 CRC Alarm Threshold
DE0B
Direct I/O Channel 2 CRC Alarm Events
DE0C
Reserved (4 items)
DE10
Direct I/O Ch 1 Unreturned Messages Alarm Function
DE11
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
DE12
Direct I/O Ch 1 Unreturned Messages Alarm Threshold
DE13
Direct I/O Ch 1 Unreturned Messages Alarm Events
DE14
Reserved (4 items)
DE18
Direct IO Ch 2 Unreturned Messages Alarm Function
DE19
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
DE1A
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
DE1B
Direct I/O Channel 2 Unreturned Messages Alarm Events
DE1C
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
E000
Remote Device 1 ID
E00A
...Repeated for module number 2
E014
...Repeated for module number 3
E01E
...Repeated for module number 4
E028
...Repeated for module number 5
E032
...Repeated for module number 6
E03C
...Repeated for module number 7
E046
...Repeated for module number 8
E050
...Repeated for module number 9
E05A
...Repeated for module number 10
E064
...Repeated for module number 11
E06E
...Repeated for module number 12
E078
...Repeated for module number 13
E082
...Repeated for module number 14
E08C
...Repeated for module number 15
E096
...Repeated for module number 16
GE Multilin
RANGE
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
T35 Transformer Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F202
"Remote Device 1 "
DEFAULT
B
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
B-33