GE T35 Instruction Manual page 261

Transformer management relay ur series
Hide thumbs Also See for T35:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 29)
ADDR
REGISTER NAME
9A19
...Repeated for module number 13
9A1B
...Repeated for module number 14
9A1D
...Repeated for module number 15
9A1F
...Repeated for module number 16
Setting Groups (Read/Write Setting)
A000
Setting Group for Modbus Comms (0 means group 1)
A001
Setting Groups Block
A002
FlexLogic to Activate Groups 2 through 8 (5 items)
A009
Setting Group Function
A00A
Setting Group Events
Setting Groups (Read Only)
A00B
Current Setting Group
Selector Switch Actuals (Read Only)
A400
Selector 1 Position
A401
Selector 2 Position
Selector Switch (Read/Write Setting) (2 modules)
A410
Selector 1 Function
A411
Selector 1 Range
A412
Selector 1 Timeout
A413
Selector 1 Step Up
A414
Selector 1 Step Mode
A415
Selector 1 Acknowledge
A416
Selector 1 Bit0
A417
Selector 1 Bit1
A418
Selector 1 Bit2
A419
Selector 1 Bit Mode
A41A
Selector 1 Bit Acknowledge
A41B
Selector 1 Power Up Mode
A41C
Selector 1 Target
A41D
Selector 1 Events
A41E
Selector 1 Reserved (10 items)
A428
...Repeated for module number 2
Flexcurves C and D (Read/Write Setting)
AC00
FlexCurve C (120 items)
AC78
FlexCurve D (120 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
AD00
Latch 1 Function
AD01
Latch 1 Type
AD02
Latch 1 Set
AD03
Latch 1 Reset
AD04
Latch 1 Target
AD05
Latch 1 Events
AD06
Latch 1 Reserved (4 items)
AD0A
...Repeated for module number 2
AD14
...Repeated for module number 3
AD1E
...Repeated for module number 4
AD28
...Repeated for module number 5
AD32
...Repeated for module number 6
AD3C
...Repeated for module number 7
AD46
...Repeated for module number 8
AD50
...Repeated for module number 9
AD5A
...Repeated for module number 10
AD64
...Repeated for module number 11
AD6E
...Repeated for module number 12
GE Multilin
RANGE
0 to 5
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 5
1 to 7
1 to 7
0 to 1
1 to 7
3 to 60
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 2
0 to 2
0 to 1
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 1
---
T35 Transformer Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
0 (Reset Dominant)
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
DEFAULT
B
0
0
0
0 (Disabled)
0 (Disabled)
0
0
1
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0
0
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0
B-25