Advertisement

5.4 FLEXLOGIC™
The operands available for this relay are listed alphabetically by types in the following table.
Table 5–7: T35 FLEXLOGIC™ OPERANDS (Sheet 1 of 3)
OPERAND TYPE
OPERAND SYNTAX
CONTROL
CONTROL PUSHBTN n ON
PUSHBUTTONS
DIRECT DEVICES
DIRECT DEVICE 1On
DIRECT DEVICE 16On
DIRECT DEVICE 1Off
DIRECT DEVICE 16Off
DIRECT INPUT/
DIR IO CH1(2) CRC ALARM
OUTPUT
CHANNEL
DIR IO CRC ALARM
MONITORING
DIR IO CH1(2) UNRET ALM
DIR IO UNRET ALM
ELEMENT:
FxE 1 PKP
FlexElements™
FxE 1 OP
FxE 1 DPO
FxE 16 PKP
FxE 16 OP
FxE 16 DPO
ELEMENT
LATCH 1 ON
Non-Volatile
LATCH 1 OFF
Latches
LATCH 16 ON
5
LATCH 16 OFF
ELEMENT:
PHASE TOC1 PKP
Phase TOC
PHASE TOC1 OP
PHASE TOC1 DPO
PHASE TOC1 PKP A
PHASE TOC1 PKP B
PHASE TOC1 PKP C
PHASE TOC1 OP A
PHASE TOC1 OP B
PHASE TOC1 OP C
PHASE TOC1 DPO A
PHASE TOC1 DPO B
PHASE TOC1 DPO C
PHASE TOC2 to TOC6
ELEMENT:
SELECTOR 1 POS Y
Selector Switch
SELECTOR 1 BIT 0
SELECTOR 1 BIT 1
SELECTOR 1 BIT 2
SELECTOR 1 STP ALARM
SELECTOR 1 BIT ALARM
SELECTOR 1 ALARM
SELECTOR 1 PWR ALARM
SELECTOR 2
ELEMENT:
SRCx 50DD OP
Disturbance
Detector
ELEMENT:
XFMR INST DIFF OP
Transformer
XFMR INST DIFF OP A
Instantaneous
XFMR INST DIFF OP B
Differential
XFMR INST DIFF OP C
5-62
OPERAND DESCRIPTION
Control Pushbutton n (n = 1 to 7) is being pressed.
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
The rate of Direct Input messages received on Channel 1(2) and failing the
CRC exceeded the user-specified level.
The rate of Direct Input messages failing the CRC exceeded the user-
specified level on Channel 1 or 2.
The rate of returned direct input/output messages on Channel 1(2) exceeded
the user-specified level (ring configurations only).
The rate of returned direct input/output messages exceeded the user-
specified level on Channel 1 or 2 (ring configurations only).
FlexElement™ 1 has picked up
FlexElement™ 1 has operated
FlexElement™ 1 has dropped out
FlexElement™ 16 has picked up
FlexElement™ 16 has operated
FlexElement™ 16 has dropped out
Non-Volatile Latch 1 is ON (Logic = 1)
Non-Voltage Latch 1 is OFF (Logic = 0)
Non-Volatile Latch 16 is ON (Logic = 1)
Non-Voltage Latch 16 is OFF (Logic = 0)
At least one phase of PHASE TOC1 has picked up
At least one phase of PHASE TOC1 has operated
At least one phase of PHASE TOC1 has dropped out
Phase A of PHASE TOC1 has picked up
Phase B of PHASE TOC1 has picked up
Phase C of PHASE TOC1 has picked up
Phase A of PHASE TOC1 has operated
Phase B of PHASE TOC1 has operated
Phase C of PHASE TOC1 has operated
Phase A of PHASE TOC1 has dropped out
Phase B of PHASE TOC1 has dropped out
Phase C of PHASE TOC1 has dropped out
Same set of operands as shown for PHASE TOC1
Selector Switch 1 is in Position Y (mutually exclusive operands).
First bit of the 3-bit word encoding position of Selector 1.
Second bit of the 3-bit word encoding position of Selector 1.
Third bit of the 3-bit word encoding position of Selector 1.
Position of Selector 1 has been pre-selected with the stepping up control
input but not acknowledged.
Position of Selector 1 has been pre-selected with the 3-bit control input but
not acknowledged.
Position of Selector 1 has been pre-selected but not acknowledged.
Position of Selector Switch 1 is undetermined when the relay powers up and
synchronizes to the 3-bit input.
Same set of operands as shown above for SELECTOR 1
Source x Disturbance Detector is operated
At least one phase of Transformer Instantaneous Differential has operated
Phase A of Transformer Instantaneous Differential has operated
Phase B of Transformer Instantaneous Differential has operated
Phase C of Transformer Instantaneous Differential has operated
T35 Transformer Management Relay