E.2 DNP POINT LISTS
Table E–6: ANALOG INPUT POINTS (Sheet 3 of 4)
POINTS
DESCRIPTION
16
SRC 1 Zero Sequence Current Angle
17
SRC 1 Positive Sequence Current Magnitude
18
SRC 1 Positive Sequence Current Angle
19
SRC 1 Negative Sequence Current Magnitude
20
SRC 1 Negative Sequence Current Angle
21
SRC 1 Differential Ground Current Magnitude
22
SRC 1 Differential Ground Current Angle
23
SRC 1 Phase AG Voltage RMS
24
SRC 1 Phase BG Voltage RMS
25
SRC 1 Phase CG Voltage RMS
26
SRC 1 Phase AG Voltage Magnitude
27
SRC 1 Phase AG Voltage Angle
28
SRC 1 Phase BG Voltage Magnitude
29
SRC 1 Phase BG Voltage Angle
30
SRC 1 Phase CG Voltage Magnitude
31
SRC 1 Phase CG Voltage Angle
32
SRC 1 Phase AB Voltage RMS
33
SRC 1 Phase BC Voltage RMS
34
SRC 1 Phase CA Voltage RMS
35
SRC 1 Phase AB Voltage Magnitude
36
SRC 1 Phase AB Voltage Angle
E
37
SRC 1 Phase BC Voltage Magnitude
38
SRC 1 Phase BC Voltage Angle
39
SRC 1 Phase CA Voltage Magnitude
40
SRC 1 Phase CA Voltage Angle
41
SRC 1 Auxiliary Voltage RMS
42
SRC 1 Auxiliary Voltage Magnitude
43
SRC 1 Auxiliary Voltage Angle
44
SRC 1 Zero Sequence Voltage Magnitude
45
SRC 1 Zero Sequence Voltage Angle
46
SRC 1 Positive Sequence Voltage Magnitude
47
SRC 1 Positive Sequence Voltage Angle
48
SRC 1 Negative Sequence Voltage Magnitude
49
SRC 1 Negative Sequence Voltage Angle
50
SRC 1 Three Phase Real Power
51
SRC 1 Phase A Real Power
52
SRC 1 Phase B Real Power
53
SRC 1 Phase C Real Power
54
SRC 1 Three Phase Reactive Power
55
SRC 1 Phase A Reactive Power
56
SRC 1 Phase B Reactive Power
57
SRC 1 Phase C Reactive Power
58
SRC 1 Three Phase Apparent Power
59
SRC 1 Phase A Apparent Power
60
SRC 1 Phase B Apparent Power
61
SRC 1 Phase C Apparent Power
62
SRC 1 Three Phase Power Factor
63
SRC 1 Phase A Power Factor
64
SRC 1 Phase B Power Factor
65
SRC 1 Phase C Power Factor
66
SRC 1 Frequency
67
Transformer Reference Winding
E-16
Table E–6: ANALOG INPUT POINTS (Sheet 4 of 4)
POINTS
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
T35 Transformer Management Relay
DESCRIPTION
Transformer Differential Phasor Iad Magnitude
Transformer Differential Phasor Iad Angle
Transformer Restraint Phasor Iar Magnitude
Transformer Restraint Phasor Iar Angle
Transformer Differential 2nd Harm Iad Magnitude
Transformer Differential 2nd Harm Iad Angle
Transformer Differential 5th Harm Iad Magnitude
Transformer Differential 5th Harm Iad Angle
Transformer Differential Phasor Ibd Magnitude
Transformer Differential Phasor Ibd Angle
Transformer Restraint Phasor Ibr Magnitude
Transformer Restraint Phasor Ibr Angle
Transformer Differential 2nd Harm Ibd Magnitude
Transformer Differential 2nd Harm Ibd Angle
Transformer Differential 5th Harm Ibd Magnitude
Transformer Differential 5th Harm Ibd Angle
Transformer Differential Phasor Icd Magnitude
Transformer Differential Phasor Icd Angle
Transformer Restraint Phasor Icr Magnitude
Transformer Restraint Phasor Icr Angle
Transformer Differential 2nd Harm Icd Magnitude
Transformer Differential 2nd Harm Icd Angle
Transformer Differential 5th Harm Icd Magnitude
Transformer Differential 5th Harm Icd Angle
Tracking Frequency
FlexElement 1 Actual
FlexElement 2 Actual
FlexElement 3 Actual
FlexElement 4 Actual
FlexElement 5 Actual
FlexElement 6 Actual
FlexElement 7 Actual
FlexElement 8 Actual
FlexElement 9 Actual
FlexElement 10 Actual
FlexElement 11 Actual
FlexElement 12 Actual
FlexElement 13 Actual
FlexElement 14 Actual
FlexElement 15 Actual
FlexElement 16 Actual
Current Setting Group
APPENDIX E