GE T35 Instruction Manual page 282

Transformer management relay ur series
Hide thumbs Also See for T35:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
F506|
BITFIELD: 1 PHASE ELEMENT STATE
0 = Pickup, 1 = Operate
F507
BITFIELD: COUNTER ELEMENT STATE
B
0 = Count Greater Than, 1 = Count Equal To, 2 = Count Less Than
F509
BITFIELD: SIMPLE ELEMENT STATE
0 = Operate
F511
BITFIELD: 3-PHASE SIMPLE ELEMENT STATE
0 = Operate, 1 = Operate A, 2 = Operate B, 3 = Operate C
F515
ENUMERATION ELEMENT INPUT MODE
0 = SIGNED, 1 = ABSOLUTE
F516
ENUMERATION ELEMENT COMPARE MODE
0 = LEVEL, 1 = DELTA
F518
ENUMERATION: FLEXELEMENT™ UNITS
0 = Milliseconds, 1 = Seconds, 2 = Minutes
F519
ENUMERATION: NON-VOLATILE LATCH
0 = Reset-Dominant, 1 = Set-Dominant
F520
ENUMERATION: TRANSFORMER REFERENCE WINDING
bitmask
Transformer Reference Winding
0
Automatic Selection
1
Winding 1
2
Winding 2
3
Winding 3
4
Winding 4
5
Winding 5
6
Winding 6
F522
ENUMERATION: TRANSDUCER DCMA OUTPUT RANGE
0 = –1 to 1 mA; 1 = 0 to 1 mA; 2 = 4 to 20 mA
B-46
F530
ENUMERATION: FRONT PANEL INTERFACE KEYPRESS
bitmask
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
F600
UR_UINT16: FLEXANALOG PARAMETER
Corresponds to the modbus address of the value used when this
parameter is selected. Only certain values may be used as Flex-
Analogs (basically all metering quantities used in protection)
MMI_FLASH ENUMERATION
Flash message definitions for Front-panel MMI
bitmask
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
T35 Transformer Management Relay
keypress
bitmask
None
22
Value Down
Menu
23
Message Up
24
7
25
~
8
26
9
31
Help
32
Message Left
33
4
34
5
35
6
36
Escape
37
Message Right
38
1
39
2
40
User PB 10
3
41
User PB 11
Enter
42
User PB 12
Message Down
44
0
45
Decimal
46
+/–
47
Value Up
Flash Message
ADJUSTED VALUE HAS BEEN STORED
ENTERED PASSCODE IS INVALID
COMMAND EXECUTED
DEFAULT MESSAGE HAS BEEN ADDED
DEFAULT MESSAGE HAS BEEN REMOVED
INPUT FUNCTION IS ALREADY ASSIGNED
PRESS [ENTER] TO ADD AS DEFAULT
PRESS [ENTER] TO REMOVE MESSAGE
PRESS [ENTER] TO BEGIN TEXT EDIT
ENTRY MISMATCH - CODE NOT STORED
PRESSED KEY IS INVALID HERE
INVALID KEY: MUST BE IN LOCAL MODE
NEW PASSWORD HAS BEEN STORED
PLEASE ENTER A NON-ZERO PASSCODE
NO ACTIVE TARGETS (TESTING LEDS)
OUT OF RANGE - VALUE NOT STORED
RESETTING LATCHED CONDITIONS
APPENDIX B
keypress
Reset
User 1
User 2
User 3
User PB 1
User PB 2
User PB 3
User PB 4
User PB 5
User PB 6
User PB 7
User PB 8
User PB 9
User 4
User 5
User 6
User 7
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents