Rev 1.6
Table 16 - Fan Status Front LED Assignments
LED
Behavior
Solid Green All fans are up and running.
Solid Red
Error, one or more fans are not operating prop-
erly.
Off
System boot
Table 17 - Fan Status Rear LED Assignments (One LED per Fan)
LED
Behavior
Solid Green A specific fan unit is operating.
Solid Red
A specific fan unit is missing or not
operating properly.
Off
System boot
56
Mellanox Technologies
Figure 57: Fan Status LED in SN2100
The SN2100 systems have a
front fan LED only.
Description
Table 17
does not apply to the SN2100 systems.
Description
Risk of Electric Shock!
With the fan module removed, power pins are accessible within the module cavity.
Do not insert tools or body parts into the fan module cavity.
Action Required
N/A
The faulty FRUs should be replaced.
N/A
Action Required
N/A
The fan unit should be replaced.
N/A
Interfaces