CAUTION
Risk of electric shock and
energy hazard. The two power
supply units are independent.
Disconnect all power supplies to
ensure a powered down state
inside of the switch platform.
2.8

System Bring-Up

For bring-up of a switch system with MLNX-OS operating system installed, refer to
2.8.1.
For bring-up of a switch system with Cumulus Linux operating system installed, refer to
2.8.2.
2.8.1

Configuring Network Attributes Using MLNX-OS

The procedures described in this chapter assume that you have already installed and powered on
the system according to the instructions in this document. The system comes with a pre-config-
ured DHCP. If you wish to disable it, refer to
(DHCP)". In case a manual configuration is required, please refer to the instructions in
2.8.1.1.
2.8.1.1 Manual Host Configuration
 To perform initial configuration of the system:
Connect a host PC to the Console RJ45 (
Step 1.
cable (DB9 to RJ45). Make sure to connect to the Console RJ45 port and not to the (Ethernet)
MGT (
42
Mellanox Technologies
After inserting a power cable and confirming the green System Status LED light is
on, make sure that the Fan Status LED shows green.
If the Fan Status LED is not green, unplug the power connection and check that the
fan module is inserted properly and that the mating connector of the fan unit is free of
any dirt and/or obstacles. If no obstacles were found and the problem persists, call
your Mellanox representative for assistance.

Figure 49: Two Power Inlets - Electric Caution Notifications

Gafahr des elektrischen
Schocks. Entferrnen des
Netzsteckers elnes Netz-
teils spannungsfrei. Um
alle Einhieten spannungs-
frei zu machen sind die
Netzstecker aller Netzteile
zu entfernen
) port.
ACHTUNG
Risque de choc et de danger
e'lectriques. Le de'branch-
ment d'une seule alimentation
stabilise'e ne de'branch
uniquement qu'un module
"Alimentation Stabilise'e".
Pour isoler completement le
module en cause, Il faut
de'brancher toutes les alimen-
tations stabilise'es.
"Disable Dynamic Host Configuration Protocol
) port of the system, using the supplied harness
ATTENTION
Section
Section
Section