Problem: Starter button not effective
Condition
1. Battery charge low
2. Switch contacts defective
3. Starter motor brushes not seating
4. Starter relay defective
5. Emergency stop - ignition switch off
6. Wiring connections loose - disconnected
7. Clutch position switch defective
Problem: Battery discharges too rapidly
Condition
1. Electrical load too high
2. Battery short-circuited
Problem: Battery polarity reversed
Condition
1. Battery incorrectly connected
www.mymowerparts.com
Back
11-8
Back to TOC
Remedy
1. Recharge - replace battery
2. Replace switch
3. Repair - replace brushes
4. Replace relay
5. Turn on switches
6. Connect - tighten - repair connections
7. Replace switch
Remedy
1. Reduce electrical load
2. Replace battery
Remedy
1. Reverse connections - replace battery