%Apr 26 16:46:32:169 2012 HPE DRVMSG/1/InSufficientPwr:
No sufficient power, failed to power on slot 3.
Execute the display version command to verify that the LPU is in position:
4.
Slot3:
The Board is present, state is unknown
If the problem persists, contact Hewlett Packard Enterprise Support.
5.
RUN LED fast flashes
Symptom
20 minutes after the router is powered on or the LPU is inserted into the router, the RUN LED for the
LPU still fast flashes at 8 Hz. If you enter the display device command, the system displays the
following output:
<Sysname> display device
Slot No.
---------------------------------------------------------------------
1/0
1/1
1/2
1/3
The output shows that LPU in slot 2 has failed.
Solution
To resolve the problem, contact Hewlett Packard Enterprise Support.
Power supply failures
Power LED is off
Symptom
The router cannot be powered on and the power LED on the front panel is off.
Solution
To resolve the problem::
Verify that the power switch is turned on.
1.
Verify that the power cords of the router are correctly connected.
2.
Verify that the switch of the power source is turned on.
3.
Verify that the power cord is not damaged.
4.
If the problem persists, contact Hewlett Packard Enterprise Support.
5.
Red power LED is on
Symptom
The router cannot be powered on and the red power LED on the front panel is on.
Solution
To resolve the problem::
Board type
Status
N/A
Absent
RSE-X2
Normal
FIP-600
Startup
FIP-600
Normal
Primary
SubSlots
N/A
N/A
Master
0
N/A
2
N/A
2
60