Displaying The Alarming Thresholds Of A Card; Port Configuration And Management; Configuring A Combo Interface - HP FlexNetwork HSR6800 Installation Manual

Hide thumbs Also See for FlexNetwork HSR6800:
Table of Contents

Advertisement

Displaying the alarming thresholds of a card

Use the display environment command to display the temperature information and alarming
thresholds of a card.
<Sysname> display environment
System temperature information (degree centigrade):
------------------------------------------------------------------------------
Slot
Sensor
1/Vent Hotspot 1 25
1/1
Outflow 1 29
1/1
Hotspot 1 34
Table 20 Command output
Field
System Temperature information
(degree centigrade)
sensor
Slot
Temperature
LowerLimit
WarningLimit
AlarmLimit
ShutdownLimit

Port configuration and management

Configuring a combo interface

A combo interface is a logical interface that comprises an SFP port of a transceiver module and an
RJ-45 Ethernet port. The two ports share one forwarding interface, so they cannot work
simultaneously. When you enable either port, the other port is automatically disabled. You can select
to activate a port as needed.
Use the display interface interface-type interface-number command to find out which port is an SFP
port and which port is an RJ-45 Ethernet port.
If the output includes "Media type is optical fiber," it means that the port is an SFP port. For
example, the following output shows that GigabitEthernet 5/0/1 is an SFP port.
[Sysname] display interface GigabitEthernet 5/0/1
Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
0
0
0
Description
Temperature information (°C).
Temperature sensor:
hotspot—Hotspot sensor.
inflow—Air inlet sensor.
outflow—Air outlet sensor.
A number in this field indicates a card. The value vent indicates a
sensor on the frame or fan tray. (In standalone mode.)
The chassis-number/slot-number in this field indicates a card on
an IRF member device. A value in the format chassis-number/ven
indicates a sensor on the frame or fan tray of an IRF member
device. (In IRF mode.)
Current temperature.
Lower temperature limit.
Warning temperature threshold.
Alarming temperature threshold.
Shutdown temperature threshold. When the sensor temperature
reaches the limit, the system shuts down automatically.
120
255
54
58
72
77
54
255
255
255