Figure 11 Installing a power supply

Installing MPUs and switching fabric modules

Installing an MPU

CAUTION:
The RUN LED flashes fast when the MPU is starting up. Do not install or remove the MPU during this
period to avoid hardware damage.
Before installing an MPU, pivot the ejector levers on the MPU outward.
Slot 4 on the HSR6808 does not have a filler panel.
The installation procedures for the RSE-X2 and RSE-X3 MPUs are the same. The following
procedure uses the RSE-X2.
To install an MPU:
Face the front of the router and locate the slot to be used.
1.
Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
2.
Keep the removed filler panel for future use.
Skip this step if you are installing the MPU to slot 4 of an HSR6808 router.
Insert the MPU slowly along the slide rails until it makes close contact with the backplane, and
3.
then push the ejector levers inward to lock the MPU in position.
Use a Phillips screwdriver to fasten the captive screws on the two sides of the MPU.
4.
For the MPU LED description, see
Figure 12 Installing an MPU

Installing an SFE-X1 switching fabric module

Only the Slot 6 of the HSR6808 supports the SFE-X1 switching fabric module.
Before installing an SFE-X1 switching fabric module, pivot the ejector levers on the SFE-X1
switching fabric module outward.
To install an SFE-X1:
"MPU and switching fabric module
14
LEDs."