Network Interface Modules; Netvanta 56K/64K Nim (P/N 1200861L1); Figure 8. Netvanta 56K/64K Nim - ADTRAN NetVanta 3000 Series Hardware Installation Manual

Routers
Hide thumbs Also See for NetVanta 3000 Series:
Table of Contents

Advertisement

NetVanta 3000 Series Hardware Installation Guide

Network Interface Modules

NetVanta 56K/64K NIM (P/N 1200861L1)

The 56K/64K NIM (shown in Figure 8) provides a WAN interface for the NetVanta 3000 Series. This
module provides a single 56K or 64K DDS network interface. Refer to Table A-5 on page 53 for the WAN-
DDS connector pinout, and refer to Table A-12 on page 56 for the DBU connector pinout. An optional
DIM is required for dial backup applications.
Features and Specifications
Operating Modes
Dedicated DDS (leased line)
DDS Interface
RJ-48C
4-wire, full duplex
-45 dB receiver sensitivity all rates
Data Rates: 56K, 64K, and Auto
Clock Source
Network
Internal
Diagnostics
CSU and DSU Loopbacks
61200860L1-34E

Figure 8. NetVanta 56K/64K NIM

© 2004 ADTRAN, Inc.
Relevant Requirements/Standards
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
ACTA/FCC Part 68
Industry Canada CS03
UL and CUL
AT&T TR 62310
Environmental
Operating Temperature: 0 °C to 50
Storage Temperature: -40 °C to 85
Relative Humidity: Up to 95%
noncondensing
Physical
Dimensions: 4.25" x 2.75"
Option Modules