Rev. 10/27/2009
991
Software error 2
The software performs an
unexpected function. However,
C
unlike SC990, recovery
processing allows the program to
continue.
*1: In order to get more details about SC990 and SC991:
1.
Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most
recent logged errors.
2.
If you press the zero key on the operation panel with the SP selection menu displayed,
you will see detailed information about the recently logged SC990 or SC991, including
the software file name, line number, and so on. 1) is the recommended method,
because another SC could write over the information for the previous SC.
Printer font error
992
A necessary font is not found in
the SD card.
⇒
998
Application start error
No applications start within 60
seconds after the power is turned on.
SM
Software defective, re-boot*1
A necessary font is not found in the
SD card.
The SD card data is corrupted.
Check that the SD card stores
correct data.
Loose connection of
RAM-DIMM, ROM-DIMM
Defective controller
Software problem
1. Check if the RAM-DIMM and
ROM-DIMM are correctly connected.
2. Reinstall the controller system
firmware.
3. Replace the controller board.
4-17
Service Call Conditions
G176/G177/G176L