Ricoh G176 Service Manual page 128

Table of Contents

Advertisement

Printer Engine Service Mode
Proxy Port Number
This SP sets the port number of the proxy server used for communication
between embedded RCG-N and the gateway. This setting is necessary to
5816 064
set up embedded RCG-N.
Note: This port number is customer information and is not printed in the
SMC report.
Proxy/User Name
This SP sets the HTTP proxy certification user name.
Note:
5816 065
The length of the name is limited to 31 characters. Any character
beyond the 31st character is ignored.
This name is customer information and is not printed in the SMC report.
Proxy Password
This SP sets the HTTP proxy certification password.
5816 066
The length of the name is limited to 31 characters. Any character
beyond the 31st character is ignored.
This name is customer information and is not printed in the SMC report.
Cert: Vp State
Displays the status of the certification update.
0
The certification used by embedded RCG is set correctly.
The certification request (setAuthKey) for update has been received
1
from the GW URL and certification is presently being updated.
5816 067
The certification update is completed and the GW URL is being
2
notified of the successful update.
The certification update failed, and the GW URL is being notified of the
3
failed update.
The period of the certification has expired and new request for an
4
update is being sent to the GW URL.
G176/G177/G176L
5-26
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G177G176l