Automatic Mode - JUMO mTRON T Operating Manual

Measuring, control, and automation system process engineering application
Hide thumbs Also See for mTRON T:
Table of Contents

Advertisement

2.3.7

Automatic mode

After the program start, the process screen for automatic mode is displayed.
Process screen
(1)
(2)
(1) Status bar:
Symbol for the program generator status
(in this case: automatic mode)
Program generator number (in this case: 1)
"P" symbol (program) and program name
"Alarm" symbol
"Event" symbol
Current program section (in this case: 2)
and number of program cycles (in this case
3/6; the program is in the third cycle of a
total of six cycles, this is equal to 5 repeti-
tions)
(2) Control elements (from left to right):
Detailed information
Temporary changes to the program (pro-
gram editor)
Previous section
Program abort (with additional confirmation
prompt)
Next section
Pause
Back (overview screen)
2 Process screen operation
(3) Display of process data:
Active process step
Actual values (orange) and setpoint values
(green) of the plant
Program run time (orange) and remaining
running time (green)
Symbols to identify process data (see
below)
(3)
33