3 Configuration
Set changeover condition (time/setpoint value)
In the same window, the condition for section changeover is also defined:
Section changeover:
Time: after expiry of section time
Setpoint value: after reaching the setpoint value (core temperature = core setpoint value)
(No section time can be entered in the program plan.)
Time and setpoint value: after expiry of section time AND after reaching the setpoint value
Time or setpoint value: after expiry of section time OR after reaching the setpoint value
Time != 0 or Setp. ! = NoInput: special option with no meaning in the process engineering
application (in this case, has the same function as "time or setpoint value").
Setpoint value 3 (T_core) was previously selected as the setpoint value for the section change-
over (core setpoint value).
54