2 Process screen operation
Edit program
After pressing the "start program editor" control element (button), the program editor process
screen is displayed:
(1)
(2)
(1) Status bar:
"Edit program" symbol
"P" symbol (program) and program name
"P/i" symbol (number of program sections;
in this case: 3)
(2) Control elements (from left to right):
Previous section
Selected section (direct selection possible
by entering section number)
Next section
Insert empty section after the selected sec-
tion
Delete selected section
Copy selected section to cache
Insert copied section into any position in
the same program
Back (basic status)
Process step
When editing a program section, the process step must first be specified. The process step de-
termines which setpoint values are available and which limits are valid for the section time.
Process steps are created via configuration with the setup program.
Chapter 3.4 "Process steps", page 48
24
(3) Program sections:
Previous section (for information only)
Selected section
Next section (for information only)
(4) Selected program section (partially edit-
able):
Section number (not editable)
Process step
Section time
Target (start section of the repetition)
Cycles (number of repetitions)
Setpoint values 1 to 8
Operating contacts 1 to 8
Setpoint values and section time are dis-
played in red in the case of limit value vio-
lation.
(3)