3 Configuration
Use setpoint value as setpoint value controller of the multichannel controller module
[Module] > Configuration level > NV connecting list (> Analog signal):
In this example, setpoint value 1 (Channel 1 SP1) of program generator 1 is connected with an
input signal (NV_C01Setpoint) of the multichannel controller module.
This signal is designated as a setpoint value for the first controller channel (controller 1) of the
module, but it must also be selected in the controller configuration as an input signal.
[Module] > Configuration level > Controller (> Controller 1 > Controller input):
In this example, the input signal (NV_C01Setpoint) of the multichannel controller module is
connected with the setpoint value input of the first controller channel (Controller 1).