Start the program
After selecting the program – and, if necessary, entering the start section and lead time – the
program can be started.
(1)
(2)
(1) Status bar:
"Program generator in basic status" symbol
Program generator number (in this case: 2)
"P" symbol (program) and program name
(2) Control elements (from left to right):
Detailed information about the program
generator
Adopt program for the program generator
and start later (lead time will be observed
automatically)
Start program (lead time will be observed
automatically)
Back (without program selection)
2 Process screen operation
(3) Selected program:
Program name is displayed (reselection
possible)
Red background for limit value violation
due to setpoint value: the program can not
be adopted for the corresponding program
generator.
(4) Entered start section:
Section number is displayed (reselection
possible)
(5) Starting time (after pressing the start but-
ton):
Running (current) time: program starts
immediately
Time (date and time): program starts at the
displayed time
Time span (hh:mm:ss): program starts after
time span has elapsed
(3)
(4)
(5)
31