Looking For The Wwn Address Of A Fibre Channel Controller - Fujitsu PRIMERGY CX2550 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures
The addresses are displayed at the one or more of the following (it depends on
the behavior of the UEFI driver included in each controller).
1. The addresses are displayed at the UEFI driver menu included in each
controller in the Configuration menu.
2. Select the UEFI driver menu included in each controller. The addresses are
displayed at the help for the UEFI driver menu included in each controller.
3. Enter the Network Device List menu. The addresses are displayed in the
Network Device List menu.
Only network controllers supporting the Command Line Protocol (CLP)
will be displayed.
Using the iRMC S5 web interface
▶ Log in to the iRMC S5 web interface.
▶ Open the System menu.
▶ Open the Network page.
▶ In the Network Adapters group, you will find detailed information on each
network controller in the managed PRIMERGY server, including its MAC
address.
This information is only available with the iRMC S5 or above. Only
network controllers supporting the Command Line Protocol (CLP) will
be displayed.
For add-in cards the vendors provide documentation and tools,
offered on the Fujitsu support web pages:
https://ts.fujitsu.com/support/
Select the server, select Downloads - More Details - Driver. Some
vendors bundle the documentation together with the driver package.
5.2.14.3

Looking for the WWN address of a fibre channel controller

There are several possible locations where these addresses can be found.
▶ Inform the customer about the new or changed WWN address.