Initialization Of Position Data For Sq Direct Function; Confirming The Position Data For Sq Direct Function (Position Jump ); Saving The Position Data For Sq Direct Function To Usb - Mitsubishi R56TB Instruction Manual

Cr750/crn-700 series
Table of Contents

Advertisement

11.3.4.

Initialization of position data for SQ Direct Function

Select the position data to initialize (<a>), and tap the [Delete] button (<b>). The confirmation message is shown up,
after that tap the [Yes] button. The values of selected position data are initialized.
CAUTION
When the [Yes] button of the confirmation message is tapped, the position data of the selected
position variable are initialized (cleared) in the controller.
11.3.5.

Confirming the position data for SQ Direct Function (Position jump )

The robot can be moved to the teaching position and the position can be checked.
Please refer to "11.2.5 Confirming the position data (Position jump)" for detail operation.
11.3.6.

Saving the position data for SQ Direct Function to USB

Position data for SQ Direct Function cannot be saved to the USB memory from the SQ Direct position edit screen
of controller.
Tap the [Program list] button, display the Program list screen and use the copy function. Please refer to "11.3.7
Copy position data for SQ Direct Function from controller to USB" for details.
<a>
<b>
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

R57tb