H3C S5600 SERIES Operation Manual page 1019

Hide thumbs Also See for S5600 SERIES:
Table of Contents

Advertisement

To do...
Configure the source port
Configure the number of
probes per test
Configure the automatic test
interval
Configure the probe timeout
time
Configure the maximum
number of history records that
can be saved
Configure the type of service
Start the test
Display test results
8)
Configuring UDP test on HWPing client
Follow these steps to configure UDP test on HWPing client:
To do...
Enter system view
Enable the HWPing client
function
Create a HWPing test group
and enter its view
Configure the test type
Configure the destination
address
Use the command...
source-port port-number
count times
frequency interval
timeout time
history-records number
tos value
test-enable
display hwping results
[ admin-name operation-tag ]
Use the command...
system-view
hwping-agent enable
hwping administrator-name
operation- tag
test-type { udpprivate |
udppublic }
destination-ip ip-address
1-13
Remarks
Optional
By default, no source port is
specified.
Optional
By default, one probe is made
per time.
Optional
By default, the automatic test
interval is zero seconds,
indicating no automatic test will
be made.
Optional
By default, a probe times out in
three seconds.
Optional
By default, the maximum
number is 50.
Optional
By default, the service type is
zero.
Required
Required
The display command can be
executed in any view.
Remarks
Required
By default, the HWPing client
function is disabled.
Required
By default, no test group is
configured.
Required
By default, the test type is
ICMP.
Required
This IP address and the one
configured on the HWPing
server for listening service must
be the same.
By default, no destination
address is configured.

Advertisement

Table of Contents
loading

Table of Contents