8.1.3 Exhaust Channel and Exhaust Blower Maintenance

Exhaust channels and the exhaust blower are located on the left hand side of the stove. The
following procedure demonstrates how to perform inspection and cleaning:
In order to access the exhaust channels, open the left side decorative panels.
Using a Philips or Robertson screwdriver, remove both clean-out traps by unlocking them.
Push the screw and give it a counter-clockwise quarter turn.
Locate both openings. Using the provided scraper, remove the dirt in the bottom channel of
the heat exchangers. Use an ash vacuum to complete the cleaning operation.