Hopper Lid Open; Power Loss - Enerzone Euromax EP00070 Installation And Operation Manual

Table of Contents

Advertisement

ONCE THE MAINTENANCE DONE, FOLLOW THESE INSTRUCTIONS
After 3 attempts press restart
999333555

9.3.7 Hopper Lid Open

The hopper lid remained open for more than 3 minutes. As a security measure, the
auger stops turning and feeding pellets as soon as the hopper lid opens. It will resume
normal operation as soon as the hopper lid is closed. If the hopper lid stays open for more
than 3 minutes, the stove will stop.
The hopper lid safety switch is faulty or disconnected. Make sure that the switch
wiring is properly connected. If it is, the hopper switch may be faulty. Follow steps in the
troubleshooting page (see Section 9.2 Testing Components) and verify the proper
function of the safety switch. Replace if necessary.

9.3.8 Power Loss

Euromax Pellet Stove Installation and Operation Manual
and press accept. The system will reset.
and then enter the following code
61