8.1.2 Cleaning the Baffle, the Heat Exchanger and the Combustion Chamber

Cleaning of the heat exchanger must be done on a regular basis (see Section 8.1.1:
Recommended Maintenance Schedule). To access the heat exchanger you need to first
rise up and pull towards you the decorative grill (A) above the viewing door. Unscrew the two
wing nuts (B) and remove the access panel (C) to the heat exchangers. Take care in not
damaging the sealing gasket when putting the panel aside. Take the brush that was supplied
with the stove and insert it into each tube in a complete motion from top to bottom. IT IS
IMPERATIVE TO SLIDE THE BRUSH COMPLETY DOWN. IT WILL BE VERY DIFFICULT
TO REMOVE THE BRUSH IF IT IS STOPPED HALFWAY IN ONE OF THE TUBES. It is
recommended to use an ash vacuum to remove dust escaping from the tubes during the use
of the brush.
Using the provided sweeping rod, sweep up and down each exchanger. Make sure you go all
the way down to the bottom.
Reinstall the access panel to the combustion chamber and tighten the wing nuts.
41
Euromax Pellet Stove Installation and Operation Manual