Enerzone Euromax EP00070 Installation And Operation Manual page 53

Table of Contents

Advertisement

To validate the status of a component, you need to go to the "TROUBLESHOOT" page from
the Main Status Page. Once there you will be able to navigate with the arrows through 7
different pages.
Access to
program
VX.XX(X
) VX.XX
X:XX:X
X
Page 1 provides information on the software version of the stove's two electronic cards. In
addition, you have the total number of hours your stove has been in operation, the
temperature of the exhaust gases and the maximum temperature that your stove has
reached.
Pages 2 and 3 will give you statistics on the number of times a specific error code has
occurred.
From page 4 is the list of operating states of the electronic components. If the square is
green, it means that the operating state of the component is normal, no matter if it's on the left
column or right. If the square is red, it means that the operating condition is abnormal. This
screen will give you the operating status in real time, meaning that when the stove is running,
if a state change occurs, you will see it immediately.
WITH GREEN ICONS
WITH RED ICONS
Euromax Pellet Stove Installation and Operation Manual
XX°F
XX°F
Pressure switch is closed. This condition is
normal if the stove is in operation.
Pressure switch is open. This condition is
normal if the stove is OFF.
Pressure switch is closed. This condition is
abnormal if the stove is OFF.
Pressure switch is open. This condition is
abnormal if the stove is in operation.
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents