Auger Fuse - Enerzone Euromax EP00070 Installation And Operation Manual

Table of Contents

Advertisement

 The igniter is defective: Test the resistance (ohms, Ω) with a multimeter. If the value is
near zero, replace the igniter and the F3 fuse.
 The wiring harness shorted. Inspect the wiring and replace any defective wire and or
connector. Make sure the wires are not shorted to the stove frame. Locate the fuse F3 on
the control board and replace it. Go to the troubleshooting page (see Section 9.2 Testing
Components) and follow instructions for component check. Test the igniter to see if it
glows. It should take no longer than two minutes.

9.3.5 Auger Fuse

 The auger is jammed or auger motor failed. Go to the troubleshooting page (see
Section 9.2 Testing components) on the LCD screen and test auger motors. If one of
the motors is not running check if motor is defective or jammed.
NOTE : IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS
JAMMED, TO AVOID PELLET SPILLAGE, EMPTY THE HOPPER OF ITS CONTENTS
BEFORE EXECUTING THE FOLLOWING TESTS.
o If the auger motor is defective, check to make sure that electrical connections are not
loose and check the fuses F2 and F6 on the control board. If the fuses are good,
remove the faulty auger motor from its auger housing and retest the motor separately
still using the troubleshooting test mode. Make sure the hopper lid is closed. If the
motor functions, the auger may be jammed by a foreign object. If no signs of blockage
are found, call your dealer or a service technician to perform a complete testing.
o If the hopper auger is jammed, start by emptying the hopper. If it is the burn pot auger
you don't need to empty the hopper. To remove both augers from their housing you
need to disconnect auger motor and then remove the four screws on the steel plate
that holds the auger shaft to the auger housing. You may need to remove the rear
panel for an easier access. Pull out the auger from the housing. Once the auger has
been removed, make sure there are no metal flows, burrs, or broken welds. Remove
any foreign material that may have caused the jam. Inspect the auger housing for signs
of damage such as burrs, rough spots, or grooves cut into the metal that could have
caused a jam. Clean the auger housing thoroughly to remove all pellet dust.
 The wiring harness shorted. Make sure the auger motor wiring is properly connected
and not shorted.
Euromax Pellet Stove Installation and Operation Manual
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents