Convection Fan Speed Adjustment - Enerzone Euromax EP00070 Installation And Operation Manual

Table of Contents

Advertisement

Average speed of auger motor #1:
You may want to increase the auger motor #1 speed if fire goes out when combustion level is
at its minimum setting. When burning poor quality pellets you may also need to reduce the
auger motor speed to avoid unburned pellets to fall into the ash drawer at any combustion
level.
Speed of combustion fan:
You may want to reduce combustion fan speed if fire goes out when combustion level is at
minimum setting. You may also want to increase combustion fan speed to avoid unburned
pellets to fall into the ash drawer at any combustion level.
Speed of exhaust fan:
You may want to reduce exhaust fan speed if natural draft is excessive and/or if the flame is
low and almost at the same height at any combustion level. You may also want to increase
the exhaust fan speed if vent configuration is too restrictive or flame height tends to be high at
any combustion level.

6.1.7 Convection Fan Speed Adjustment

You can adjust the stove's convection fan speed for each combustion level selected. Thus, an
adjustment range is offered to reduce or increase air distribution in the room. Take note that
not all fan ranges are available, but the speed of the convection blower is consistent with the
requested burn rate.
If overheating is detected, the convection fan speed will automatically go to the maximum
setting and an envelope icon will appear on the Main Status Page. Press on the envelope
icon to view the warning message. Meanwhile, the convection fan will operate at its highest
setting until the stove reaches a safe temperature. Once the stove reaches that temperature,
it will return to the previously selected convection fan selection.
Euromax Pellet Stove Installation and Operation Manual
Press the blower
button to adjust the
blowing speed
Press + or -
to increase
or decrease
blower speed
33