3 Clearances to Combustible Material

The clearances shown in this section have been determined by tests according to procedures
set out in safety standards ULC S627 (Canada), ASTM E1509 (U.S.A). When the pellet stove
is installed so that its surfaces are at, or beyond, the minimum clearances specified,
combustible surfaces will not overheat under normal and even abnormal operating conditions.
WARNING: NO PART OF THE STOVE MAY BE LOCATED CLOSER TO COMBUSTIBLES
THAN THE MINIMUM CLEARANCES SPECIFIED ON THE CERTIFICATION LABEL.
CAUTION: NO PART OF THE PELLET VENT SYSTEM MAY BE LOCATED CLOSER TO
COMBUSTIBLES THAN THE MINIMUM CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
CAUTION: DO NOT USE MAKESHIFT MATERIALS OR MAKE ANY COMPROMISES
WHEN INSTALLING THIS STOVE.

3.1 Certification Label Location

Since the information given on the certification label affixed to the stove always overrides the
information published in any other media (owner's manual, catalogues, flyers, magazines
and/or web sites), it is important to refer to it in order to have a safe and compliant installation.
In addition, you will find important information about your stove (model, serial number, etc.).
You will find the certification label on the inner side of the hopper lid of the stove.

3.2 Minimum Clearances to Combustibles

LETTER
A
B
C
D
I
Note: We recommend leaving 24" on each side of the stove and 12" at the back of the
stove in order to facilitate access for maintenance.
12
CLEARANCES TO COMBUSTIBLES
CANADA
3" (76 mm)
6" (152 mm)
3" (76 mm)
Refer to vent
manufacturer's clearances
72" (1 829 mm)
USA
3" (76 mm)
6" (152 mm)
3" (76 mm)
Refer to vent manufacturer's
clearances
72" (1 829 mm)
Euromax Pellet Stove Installation and Operation Manual