 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS
UNIT.
 DO NOT CONNECT THIS STOVE TO ANY OTHER EXISTING VENTING SYSTEM
SERVING ANOTHER APPLIANCE.
 DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK.
 THE VENTING SYSTEM MUST BE COMPLETELY AIRTIGHT AND PROPERLY
INSTALLED. ALL VENT CONNECTOR JOINTS MUST BE SEALED AND FASTENED
IN ACCORDANCE WITH THE PELLET VENT MANUFACTURER'S INSTRUCTIONS TO
ENSURE CONSISTENT PERFORMANCE AND AVOID SMOKE AND ASH SPILLAGE.
 THE VENTING SYSTEM SHOULD BE CHECKED, AT LEAST TWICE A YEAR FOR
ANY BUILDUP OF SOOT OR CREOSOTE.
 NEVER BLOCK ANY LOUVERS OF THE STOVE.
 IF REQUIRED, A FRESH AIR KIT CAN BE INSTALLED TO SUPPLY COMBUSTION
AIR TO THE ROOM OR SPACE (SEE APPENDIX E: COMBUSTION AIR SUPPLY).
 MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING COMPONENTS IS PROHIBITED AND WILL VOID THE WARRANTY.
 ANY MODIFICATION OF THE STOVE THAT HAS NOT BEEN APPROVED IN WRITING
BY THE TESTING AUTHORITY IS PROHIBITED AND VIOLATES CSA B365
(CANADA), AND ANSI NFPA 211 (USA).
 STOVE BUILDER INTERNATIONAL INC. (SBI) GRANTS NO WARRANTY, IMPLIED
OR STATED, FOR THE POOR INSTALLATION OR LACK OF MAINTENANCE OF
YOUR STOVE AND ASSUMES NO RESPONSIBILITY OF ANY CONSEQUENTIAL
DAMAGES.

2.2 Regulations Covering Pellet Stove Installation

When installed and operated as described in these instructions, this pellet stove is suitable for
use as a freestanding heater in residential installations.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment
and the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of
local code requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces,
Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are
to be followed in the absence of local code requirements.
This stove must be connected to a pellet vent system complying with the requirements for
Pellet Vent in the standards UL 103, UL 641, ULC S629M, CAN/ULC S609 and ULC/ORD
C441 or to a code-approved masonry chimney with a stainless steel flue liner.