DO NOT USE PLIERS OR OTHER TOOLS TO TIGHTEN THE WING NUTS.
To clean the baffle, pivot the lock plate (A) by 90° found above the access door of the
combustion chamber. The baffle (B) will rotate and drop the accumulated fly ash. Clean and
reinstall the baffle.
1) To remove the baffle (for a replacement) pivot the lock plate (A) by 90°. When the baffle
has ended its rotation, place the lock to its initial position.
2) Lift the baffle (B) above its pivots and lower it by gently pulling towards you. To take it out
of the door, you must rotate it slowly towards you to avoid hitting the walls of the
combustion chamber.
IT IS HIGHLY RECOMMENDED TO CLEAN THE EXHAUST CHANNEL (SEE SECTION
8.1.3: EXHAUST CHANNEL AND EXHAUST BLOWER MAINTENANCE) IMMEDIATLY
AFTER CLEANING THE HEAT EXCHANGER.