8.1.9 Door Gasket Maintenance

It is important to maintain the door gasket in good condition. After a while, the gasket will
wear and compress; adjusting the door may then be required. If the door adjustment is not
sufficient, replace the door gasket with a genuine part. If the stove door is not properly sealed,
it will be difficult to keep the door glass clean and combustion gases may leak into the room.

8.1.10 Door Adjustment

In order for your stove to burn at its best efficiency, the door must provide a perfect seal with
the firebox. Therefore, the gasket should be inspected periodically making sure to obtain an
air tight fit. Air tightness can be improved with a simple latch mechanism adjustment. To
adjust:
1. Remove the lock pin by pulling and
turning with pliers. Turn the handle
counter clock wise one turn to increase
pressure.

8.2 Venting System Maintenance

CAUTION: REGULARLY EXAMINE THE VENTING SYSTEM, THE JOINTS, AND THE
SEALING TRIMS TO ENSURE THAT THE SMOKE AND THE COMBUSTION GASES ARE
NOT DRAWN BY THE CONVECTION BLOWER.
The most efficient method to sweep the venting system is by using a 4'' pellet brush
depending on your installation. Brush downwards so ash, soot and creosote residues will
come off the inner surface and fall at the bottom of the clean out tee where they can be easily
removed. The venting system must be in good condition and kept clean.
WARNING: IF A SIGNIFICANT LAYER OF CREOSOTE HAS ACCUMULATED (3MM / 1/8"
OR MORE), IT MUST BE REMOVED IMMEDIATELY TO ELIMINATE THE RISK OF A
CHIMNEY FIRE.
50
2. Re-
the lock pin (spring pin)
install
with a small hammer
Euromax Pellet Stove Installation and Operation Manual