3.6 Floor Protection

For floor protection clearances refer to the following table.
LETTER
CANADA
E
18" (457 mm)
F
N/A (USA only)
G
8" (203 mm)
H
8" (203 mm)
CAUTION: THE STOVE MUST BE PLACED ON A CONTINUOUS (GROUTED JOINTS)
NONCOMBUSTIBLE MATERIAL SUCH AS CERAMIC TILE*, CEMENT BOARD, BRICK,
MILLBOARD OR EQUIVALENT, OR ANY OTHER APPROVED OR LISTED MATERIAL
SUITED FOR FLOOR PROTECTION.
*Any type of tile will require a continuous non combustible sheet beneath to prevent the
possibility of embers falling through to the combustible floor if cracks or separation should
occur in the finished surface, this would include floor protection for built-in raised hearths.
Check local codes for approved alternatives.
14
FLOOR PROTECTION
USA
6" (152 mm)
6" (152 mm)
N/A (Canada only)
N/A (Canada only)
Euromax Pellet Stove Installation and Operation Manual