CHARGING SYSTEM
A. C generator
INSPECTION
CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the DC voltage
between the battery terminal
If the voltage is not within the specified value, check the
magneto no-load performance and regulator / rectifier.
CAUTION
When making this test, be sure that the battery is
full-charged condition.
Standard charge
Pocket tester : 09900 - 25002
Tester knob indication : Voltage (
and
.
13.5
15.0 V (at 5,000 rpm)
Regulator / Rectifier
)
ELECTRICAL SYSTEM 7-8
Ignition switch
IC
Regulator
Rectifier
Battery
IG. switch
DCV