Fins bent down or dented can be repaired by straighten-
ing them with the blade of a small screwdriver.
INSPECTION OF WATER
HOSE
Any water hose found in a cracked condition or flattened
or water leaked must be replaced.
Any leakage from the connecting section should be cor-
rected by proper tightening.
REMOUNTING
The radiator reassembly can be performed in the
reverse order of disassembly procedures.
However, the following points must be observed in the
reassembly operation.
Install the radiator with the specified torque.
Radiator mounting bolt
: 8 ~ 12 N m (0.8 ~ 1.2 kgf m)
Pour engine coolant
Bleed air from the cooling circuit
Refer to page 2-25
Refer to page 2-26
COOLING SYSTEM 6-4