5-7 ELECTRICAL SYSTEM

CHARGING SYSTEM

A. C generator
◉ ◉ INSPECTION
▣ ▣ CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the DC voltage
between the battery terminal �
If the voltage is not within the specified value, check
the magneto no-load performance and regulator /
rectifier.
CAUTION
When making this test, be sure that the battery is
full-charged condition.
Standard charge
Tester knob indication : Voltage (
and � .
13.5�15.0 V (at 5,000 rpm)
Regulator / Rectifier
)
62
IG. switch
IC
Regulator
Rectifier
Battery
IG. switch
DCV