Precautions In Operation - TGB blade 300 Service Manual

Table of Contents

Advertisement

10. ALTERNATOR/STARTING CLUTCH

Precautions in Operation

General information
● Refer to chapter 17: The troubleshooting and inspection of alternator
● Refer to chapter 17: The service procedures and precaution items of starter motor
Specification
ID of starting clutch gear
OD of starting clutch gear
Torque value
Flywheel nut
Starting clutch hexagon bolt
8 mm bolts
12 mm bolts
Tools
Special tools
A.C.G. flywheel puller: TGB-440626
Universal holder: TGB-440646
10-2
PDF created with pdfFactory Pro trial version
To this chapter contents
Item
www.pdffactory.com
Standard value (mm)
25.026~25.045
42.192~42.208
5.0~6.0kgf-m
1.0~1.4kgf-m with adhesive
0.8~1.2kgf-m
1.0~1.4kgf-m
Limit (mm)
25.050
42.100